FAQ

Q: Which Inventor versions are supported?
A: Inventor Professional 2021 or newer

Q: I am using Frame Generator parts. Is it possible that the component names are also updated?
A: Yes, it is possible. You need to change the setting ‘UpdateFunctionalDocuments’ to true, like described in chapter mightyBrowser Settings.

Q: When I open an iPart factory the browser name is not updated. Why? A: If the display name of an iPart factory would be modified already generated ipart members might not find the factory. Therfore, the app is not updating display names of iPart factories!

Q: I have set switch ‘UpdateOnOpen’ to ‘true’ in mightyBrowser.dll.config but when I call command ‘Open’ on the context menu of the browser tree, the ‘Update Browser Node’ is not done on the opened file.
A: ‘UpdateOnOpen’ is not implemented when the ‘Open’ command is called from the browser tree. If you are missing this feature, please send an email to support@coolOrange.com and ask for that feature.

Known issues

Label of sections

If switch ‘UpdateViews’ is set to true the label of the VIEW is modified. If you insert a section on the sheet, the default for the text of the section is the label of the VIEW. Therefore instead of just the expected text ‘A’ or ‘B’ a complete browser node text is displayed.

Solution: Either set configuration switch ‘UpdateViews’ in mightyBrowser.dll.config to ‘false’ or Overwrite the text for the section.

UpdateFunctionalDocuments

If switch ‘UpdateFunctionalDocuments’ is set to true in the config file, it might happen that some of the browser names of Frame Generator parts are not updated.
Workaround: Call command “Rename Browser Nodes” from the Productivity tool, and either apply Filename or Part Number as new name. Then call “Update Browser Nodes” from the coolOrange ribbon again.

Browser name of an IPN in VIEWs

Browser name of an IPN as component in a VIEW of a drawing cannot be updated.

Config file is overwritten when installing the update of mightyBrowser

If you have modified the mightyBrowser.dll.config file and run an update of mightyBrower the config file is overwritten. Therefore it is recommended to backup the config file before the update is done. Then the own settings can be transferred to the new installed config file.

Localized Display Names are not evaluated

Localized iProperty names of Inventor system properties like “Bauteilnummer” cannot be evaluated. You need to use the English Display Name of the iProperty, like “Part Number”.
Find below the list of the iProperties with the English and German Display Names:

English Display Name

German Display Name

Title

Titel

Subject

Thema

Author

Autor

Manager

Manager

Company

Firma

Category

Kategorie

Keywords

Schlüsselwörter

Part Number

Bauteilnummer

Stock Number

Bestandsnummer

Description

Bezeichnung

Revision Number

Revisionsnummer

Project

Projekt

Designer

Konstruktuer

Engineer

Ingenieur

Authority

Bevollmächtigter

Cost Center

Kostenstelle

Cost

Geschätzte Kosten

Vendor

Zulieferer

Checked by

Kontrolliert von

User Status

Status

Design Status

Konstruktionsstatus

Date Checked

Kontrolldatum

Engr Approved By

Konstruktion genehmigt von

Engr Date Approved

Genehmigungsdatum Konstr.

Mfg Approved By

Fertigung genehmigt von

Mfg Date Approved

Genehmigungsdatum Fertig

Note: “Design Status” returns a number for each status.